European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 62 - Phosphate derivatives

Code62
NamePhosphate derivatives
Source categoriesindustry, fertilizer, all sources
CountrySpain
SiteHuelva
Test year2001
TypeO
Latitude37.261
Longitude-6.945
ReferenceAlastuey et al., 2006, 10.1080/10473289.2006.10464502
Notes 
Sampling MethodsFilters collected at the the impact point of emission plume on the ground in the proximities of emission sources with Graseby Andersen reference high volume captors (EN12341, 68 m3/h). The impact points were detected with the support of a correlation spectrometer (COSPEC) and a real time SO2 analyzer at the ground. Due to the episode duration the captors sampled a low volume of air, giving rise to some artifacts (see text). The relative analytical errors are declared to be between 3% and 10% for all elements studied.
Uncertainty Noteshalf range on two samples' relative weights

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
296 - Antimony 0.00000877 0.00000015 ICP-MS, inductively coupled plasma mass spectrometry half range
298 - Arsenic 0.000587 0.000034 ICP-MS, inductively coupled plasma mass spectrometry half range
300 - Barium 0.000627 0.000015 ICP-MS, inductively coupled plasma mass spectrometry half range
328 - Cadmium 0.00009 0.000063 ICP-MS, inductively coupled plasma mass spectrometry half range
329 - Calcium 0.057 0.011 ICP-MS, inductively coupled plasma mass spectrometry half range
347 - Chromium 0.000096 0.000042 ICP-MS, inductively coupled plasma mass spectrometry half range
379 - Cobalt 0.0000079 0.0000025 ICP-MS, inductively coupled plasma mass spectrometry half range
380 - Copper 0.0088 0.0038 ICP-MS, inductively coupled plasma mass spectrometry half range
436 - Total carbon 0.0742 0.007 LECO, elemental analyzer half range
468 - Gallium 0.00000131 0.00000042 ICP-MS, inductively coupled plasma mass spectrometry half range
488 - Iron 0.021 0.0023 ICP-MS, inductively coupled plasma mass spectrometry half range
520 - Lead 0.003 0.0012 ICP-MS, inductively coupled plasma mass spectrometry half range
525 - Magnesium 0.00351 0.000062 ICP-MS, inductively coupled plasma mass spectrometry half range
526 - Manganese 0.000137 0.000042 ICP-MS, inductively coupled plasma mass spectrometry half range
586 - Molybdenum 0.000017 0.000017 ICP-MS, inductively coupled plasma mass spectrometry half range
612 - Nickel 0.0000921 0.0000028 ICP-MS, inductively coupled plasma mass spectrometry half range
613 - Nitrate 0.0189 0.0016 capillary electrophoresis half range
665 - Phosphate 0.261 0.084 capillary electrophoresis half range
669 - Potassium 0.0044 0.00095 ICP-MS, inductively coupled plasma mass spectrometry half range
693 - Selenium 0.0003334 0.0000058 ICP-MS, inductively coupled plasma mass spectrometry half range
696 - Sodium 0.082 0.035 ICP-MS, inductively coupled plasma mass spectrometry half range
697 - Strontium 0.000127 0.000011 ICP-MS, inductively coupled plasma mass spectrometry half range
699 - Sulfate 0.119 0.03 capillary electrophoresis half range
712 - Thallium 0.00000483 0.00000052 ICP-MS, inductively coupled plasma mass spectrometry half range
714 - Tin 0.000128 0.00005 ICP-MS, inductively coupled plasma mass spectrometry half range
715 - Titanium 0.00066 0.00012 ICP-MS, inductively coupled plasma mass spectrometry half range
765 - Uranium 0.000026 0.000018 ICP-MS, inductively coupled plasma mass spectrometry half range
767 - Vanadium 0.000194 0.000047 ICP-MS, inductively coupled plasma mass spectrometry half range
778 - Zinc 0.0058 0.0027 ICP-MS, inductively coupled plasma mass spectrometry half range
779 - Zirconium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry half range
784 - Ammonium 0.0378 0.005 colorimetric analysis half range
788 - Carbonate 0.0172 0.0034 indirect half range
795 - Chlorine 0.0275 0.0096 capillary electrophoresis half range
1850 - Lithium 0.00000657 0.00000032 ICP-MS, inductively coupled plasma mass spectrometry half range
1852 - Niobium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry half range
1858 - Thorium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry half range
1869 - Bismuth 0.00023 0.000092 ICP-MS, inductively coupled plasma mass spectrometry half range
2796 - Aluminum oxide 0.0194 0.003 ICP-MS, inductively coupled plasma mass spectrometry half range