European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 246 - Mat frit

Code246
NameMat frit
Source categoriesindustry, ceramic, all sources
CountrySpain
SiteCastelló
Test year2002
TypeO
Latitude39.984
Longitude-0.0449499
ReferencePandolfi et al., 2008, doi:10.1016/j.atmosenv.2008.09.031
Notesanalyzed following the methodology described by Viana et al. (2007), 10.1016/j.atmosenv.2007.12.060
Sampling Methodsmilled then high-volume(30 m3/h)sampler DIGITEL DH-80, using circular filters of quartz micro-fibre (15 cm, QF20 Schleicher and Schuell
Uncertainty Notesanalytical uncertainty

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.071191 0.005695 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
298 - Arsenic 0.000041 0.000005 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
300 - Barium 0.001048 0.000126 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
328 - Cadmium 0.00002 0.000002 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
329 - Calcium 0.06833 0.005466 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
347 - Chromium 0.000004 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
379 - Cobalt 0.000002 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
380 - Copper 0.000012 0.000001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
488 - Iron 0.000861 0.000069 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
519 - Lanthanum 0.000008 0.000001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
520 - Lead 0.000945 0.000113 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
525 - Magnesium 0.002474 0.000198 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
526 - Manganese 0.000017 0.000002 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
612 - Nickel 0.000002 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
669 - Potassium 0.028828 0.002306 IC, Ion chromatography analytical uncertainty
689 - Rubidium 0.000087 0.00001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
693 - Selenium 0.000003 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
696 - Sodium 0.013389 0.001071 IC, Ion chromatography analytical uncertainty
697 - Strontium 0.000103 0.000012 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
700 - Sulfur 0 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
712 - Thallium 0 0.000001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
714 - Tin 0.000016 0.000002 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
715 - Titanium 0.000228 0.000018 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
765 - Uranium 0.000002 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
767 - Vanadium 0.000009 0.000001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
777 - Yttrium 0.000008 0.000001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
778 - Zinc 0.162598 0.019512 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
779 - Zirconium 0.001593 0.000191 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1850 - Lithium 0.000014 0.000002 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1851 - Neodymium 0.000012 0.000001 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1853 - Praseodymium 0.000002 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1855 - Scandium 0 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1858 - Thorium 0.000003 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1861 - Cerium 0.000022 0.000003 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1862 - Cesium 0.000003 0 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty
1866 - Hafnium 0.000032 0.000004 ED-XRF energy dispersive X-ray fluorescence analytical uncertainty