European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 168 - Ferromanganese plant

Code168
NameFerromanganese plant
Source categoriesindustry, iron and steel, all sources
CountryFrance
SiteDunkirk
Test year2005
TypeD
Latitude51.035
Longitude2.375
ReferenceAlleman et al., 2010, 10.1016/j.atmosres.2010.02.008
Notes 
Sampling MethodsPMF on 108 14days samples (june 2003-March2005) in the harbour. Partisol Speciation 2300
Uncertainty Notes 

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.00942 0.01093 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
296 - Antimony not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
298 - Arsenic 0.0045 0.00044 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
300 - Barium 0.00053 0.00027 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
328 - Cadmium 0.00132 0.00008 ICP-MS, inductively coupled plasma mass spectrometry
329 - Calcium 0.06713 0.0596 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
347 - Chromium 0.00001 0.00022 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
379 - Cobalt 0.00024 0.00003 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
380 - Copper 0.00094 0.00026 ICP-MS, inductively coupled plasma mass spectrometry
488 - Iron 0.12571 0.03124 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
519 - Lanthanum not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
520 - Lead 0.03193 0.00132 ICP-MS, inductively coupled plasma mass spectrometry
525 - Magnesium 0.00009 0.00848 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
526 - Manganese 0.39774 0.00777 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
586 - Molybdenum 0.00957 0.00074 ICP-MS, inductively coupled plasma mass spectrometry
612 - Nickel 0.00027 0.00025 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
669 - Potassium 0.06753 0.03175 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
689 - Rubidium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
694 - Silicon 0.0003 0.0339 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
695 - Silver 0.00012 0.00001 ICP-MS, inductively coupled plasma mass spectrometry
696 - Sodium 0.17372 0.04663 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
697 - Strontium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
700 - Sulfur 0.07987 0.07137 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
712 - Thallium 0.00097 0.00121 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
765 - Uranium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
767 - Vanadium not detected not detected ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
778 - Zinc 0.02781 0.0027 ICP-MS, inductively coupled plasma mass spectrometry
779 - Zirconium 0.00014 0.00006 ICP-MS, inductively coupled plasma mass spectrometry
1854 - Samarium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
1855 - Scandium 0.00006 0.00003 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
1858 - Thorium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
1861 - Cerium 0.00001 0.00002 ICP-MS, inductively coupled plasma mass spectrometry
1862 - Cesium 0.00004 0.00003 ICP-MS, inductively coupled plasma mass spectrometry
1863 - Europium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
1869 - Bismuth 0.00005 0.00001 ICP-MS, inductively coupled plasma mass spectrometry