European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 57 - Phosphate derivatives

Code57
NamePhosphate derivatives
Source categoriesindustry, fertilizer, all sources
CountrySpain
SiteHuelva
Test year2001
TypeO
Latitude37.261
Longitude-6.945
ReferenceAlastuey et al., 2006, 10.1080/10473289.2006.10464502
Notes 
Sampling MethodsFilters collected at the the impact point of emission plume on the ground in the proximities of emission sources with Graseby Andersen reference high volume captors (EN12341, 68 m3/h). The impact points were detected with the support of a correlation spectrometer (COSPEC) and a real time SO2 analyzer at the ground. Due to the episode duration the captors sampled a low volume of air, giving rise to some artifacts (see text). The relative analytical errors are declared to be between 3% and 10% for all elements studied.
Uncertainty Noteshalf range on two samples' relative weights

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
296 - Antimony 0.0000124 0.0000044 ICP-MS, inductively coupled plasma mass spectrometry half range
298 - Arsenic 0.0005345 0.0000051 ICP-MS, inductively coupled plasma mass spectrometry half range
300 - Barium 0.000459 0.00007 ICP-MS, inductively coupled plasma mass spectrometry half range
328 - Cadmium 0.00009 0.000065 ICP-MS, inductively coupled plasma mass spectrometry half range
329 - Calcium 0.0415 0.0062 ICP-MS, inductively coupled plasma mass spectrometry half range
347 - Chromium 0.000116 0.00006 ICP-MS, inductively coupled plasma mass spectrometry half range
379 - Cobalt 0.0000079 0.0000039 ICP-MS, inductively coupled plasma mass spectrometry half range
380 - Copper 0.0062 0.0029 ICP-MS, inductively coupled plasma mass spectrometry half range
436 - Total carbon 0.0743 0.0021 LECO, elemental analyzer half range
468 - Gallium 0.00000124 0.00000044 ICP-MS, inductively coupled plasma mass spectrometry half range
488 - Iron 0.0156 0.0037 ICP-MS, inductively coupled plasma mass spectrometry half range
520 - Lead 0.0028 0.0013 ICP-MS, inductively coupled plasma mass spectrometry half range
525 - Magnesium 0.0062 0.003 ICP-MS, inductively coupled plasma mass spectrometry half range
526 - Manganese 0.000159 0.0000077 ICP-MS, inductively coupled plasma mass spectrometry half range
586 - Molybdenum 0.00016 0.00016 ICP-MS, inductively coupled plasma mass spectrometry half range
612 - Nickel 0.000123 0.00002 ICP-MS, inductively coupled plasma mass spectrometry half range
613 - Nitrate 0.031 0.013 capillary electrophoresis half range
665 - Phosphate 0.277 0.059 capillary electrophoresis half range
669 - Potassium 0.00448 0.00028 ICP-MS, inductively coupled plasma mass spectrometry half range
693 - Selenium 0.000226 0.000051 ICP-MS, inductively coupled plasma mass spectrometry half range
696 - Sodium 0.106 0.024 ICP-MS, inductively coupled plasma mass spectrometry half range
697 - Strontium 0.000099 0.000019 ICP-MS, inductively coupled plasma mass spectrometry half range
699 - Sulfate 0.111 0.038 capillary electrophoresis half range
712 - Thallium 0.000004 0.000004 ICP-MS, inductively coupled plasma mass spectrometry half range
714 - Tin 0.000113 0.000038 ICP-MS, inductively coupled plasma mass spectrometry half range
715 - Titanium 0.000597 0.000042 ICP-MS, inductively coupled plasma mass spectrometry half range
765 - Uranium 0.0000189 0.0000054 ICP-MS, inductively coupled plasma mass spectrometry half range
767 - Vanadium 0.000175 0.000032 ICP-MS, inductively coupled plasma mass spectrometry half range
778 - Zinc 0.0055 0.0026 ICP-MS, inductively coupled plasma mass spectrometry half range
779 - Zirconium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry half range
784 - Ammonium 0.035 0.01 colorimetric analysis half range
788 - Carbonate 0.0126 0.0017 indirect half range
795 - Chlorine 0.0353 0.0084 capillary electrophoresis half range
1850 - Lithium 0.0000049 0.00000014 ICP-MS, inductively coupled plasma mass spectrometry half range
1852 - Niobium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry half range
1858 - Thorium not detected not detected ICP-MS, inductively coupled plasma mass spectrometry half range
1869 - Bismuth 0.000218 0.0001 ICP-MS, inductively coupled plasma mass spectrometry half range
2796 - Aluminum oxide 0.0205 0.0022 ICP-MS, inductively coupled plasma mass spectrometry half range