European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 166 - Metallurgical coke fired plant

Code166
NameMetallurgical coke fired plant
Source categoriesindustry, coke, other combustion, all sources
CountryFrance
SiteDunkirk
Test year2005
TypeD
Latitude51.035
Longitude2.375
ReferenceAlleman et al., 2010, 10.1016/j.atmosres.2010.02.008
Notes 
Sampling MethodsPMF on 108 14days samples (june 2003-March2005) in the harbour. Partisol Speciation 2300
Uncertainty Notes 

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.24956 0.04118 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
296 - Antimony 0.00138 0.00016 ICP-MS, inductively coupled plasma mass spectrometry
298 - Arsenic 0.00439 0.00086 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
300 - Barium 0.00003 0.00081 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
328 - Cadmium 0.00119 0.00011 ICP-MS, inductively coupled plasma mass spectrometry
329 - Calcium 0.00084 0.07233 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
347 - Chromium not detected not detected ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
379 - Cobalt 0.00068 0.00008 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
380 - Copper 0.00432 0.00069 ICP-MS, inductively coupled plasma mass spectrometry
488 - Iron 0.00044 0.04057 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
519 - Lanthanum 0.00115 0.00008 ICP-MS, inductively coupled plasma mass spectrometry
520 - Lead 0.03443 0.00154 ICP-MS, inductively coupled plasma mass spectrometry
525 - Magnesium 0.1632 0.0414 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
526 - Manganese 0.00006 0.00288 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
586 - Molybdenum not detected not detected ICP-MS, inductively coupled plasma mass spectrometry
612 - Nickel 0.00007 0.00108 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
669 - Potassium 0.00068 0.06136 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
689 - Rubidium 0.00259 0.00023 ICP-MS, inductively coupled plasma mass spectrometry
694 - Silicon 0.00176 0.17877 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
695 - Silver 0.00028 0.00002 ICP-MS, inductively coupled plasma mass spectrometry
696 - Sodium 0.00206 0.09815 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
697 - Strontium 0.00239 0.0003 ICP-MS, inductively coupled plasma mass spectrometry
700 - Sulfur 0.41885 0.18116 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
712 - Thallium 0.03484 0.00889 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
765 - Uranium 0.00003 0 ICP-MS, inductively coupled plasma mass spectrometry
767 - Vanadium 0.00795 0.00083 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
778 - Zinc 0.06304 0.0054 ICP-MS, inductively coupled plasma mass spectrometry
779 - Zirconium 0.00124 0.00024 ICP-MS, inductively coupled plasma mass spectrometry
1854 - Samarium 0.00004 0.00001 ICP-MS, inductively coupled plasma mass spectrometry
1855 - Scandium 0.00033 0.00008 ICP-MS-DRC, IM-MS coupled with a Dynamic Reaction Cell
1858 - Thorium 0.00008 0 ICP-MS, inductively coupled plasma mass spectrometry
1861 - Cerium 0.00072 0.00007 ICP-MS, inductively coupled plasma mass spectrometry
1862 - Cesium 0.00048 0.00003 ICP-MS, inductively coupled plasma mass spectrometry
1863 - Europium 0.00001 0 ICP-MS, inductively coupled plasma mass spectrometry
1869 - Bismuth 0.00089 0.00002 ICP-MS, inductively coupled plasma mass spectrometry