European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 132 - Lead recovery furnace from car

Code132
NameLead recovery furnace from car
Source categoriesindustry, all sources
CountryTurkey
SiteIzmir
Test year2005
TypeO
Latitude38.419
Longitude27.129
ReferenceYatkin et al, 2008, 10.1016/j.chemosphere.2007.10.070
Notes 
Sampling MethodsResuspended Dust, PF 20630 Zambelli sampler, filter extraction via hot acid digestion procedure
Uncertainty Notessquare root of the quadratic sum of relative analitical uncertainties

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.0014533 0.00209 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
300 - Barium 0.0000167 0.00002 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
328 - Cadmium 0.0004219 0.00215 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
329 - Calcium 0.0004 0.00057 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
347 - Chromium 0.0000324 0.00017 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
380 - Copper 0.0015053 0.00768 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
488 - Iron 0.0029009 0.00416 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
520 - Lead 0.7505653 3.83148 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
525 - Magnesium 0.0000033 0 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
526 - Manganese 0.0000013 0 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
612 - Nickel 0.0000403 0.00021 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
669 - Potassium 0.0117333 0.01684 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
696 - Sodium 0.0053347 0.00765 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
697 - Strontium 0.0000133 0.00002 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
767 - Vanadium 0.0000466 0.00024 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
778 - Zinc 0.0043742 0.00628 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty