European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 116 - Ceramic

Code116
NameCeramic
Source categoriesindustry, ceramic, all sources
CountryTurkey
SiteIzmir
Test year2005
TypeO
Latitude38.419
Longitude27.129
ReferenceYatkin et al, 2008, 10.1016/j.chemosphere.2007.10.070
Notesfrom bag filter
Sampling MethodsResuspended Dust, PF 20630 Zambelli sampler, filter extraction via hot acid digestion procedure
Uncertainty Notessquare root of the quadratic sum of relative analitical uncertainties

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.0445166 0.0515 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
300 - Barium 0.0002155 0.00025 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
328 - Cadmium 0.0000082 0.00001 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
329 - Calcium 0.0579558 0.06705 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
347 - Chromium 0.0000598 0.00007 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
380 - Copper 0.0000907 0.00011 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
488 - Iron 0.0097104 0.01123 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
520 - Lead 0.0000619 0.00007 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
525 - Magnesium 0.0185049 0.0214 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
526 - Manganese 0.0001471 0.00017 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
612 - Nickel 0.0001013 0.00012 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
669 - Potassium 0.0055244 0.00639 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
696 - Sodium 0.0245755 0.0284 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
697 - Strontium 0.0003909 0.00045 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
767 - Vanadium 0.0000497 0.00006 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
778 - Zinc 0.0004809 0.00056 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty