European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 106 - Steel plants with electric arc furnaces

Code106
NameSteel plants with electric arc furnaces
Source categoriesindustry, iron and steel, all sources
CountryTurkey
SiteIzmir
Test year2005
TypeO
Latitude38.419
Longitude27.129
ReferenceYatkin et al, 2008, 10.1016/j.chemosphere.2007.10.070
Notesfrom bag filter of electric arc furnace of steel production from scrap
Sampling MethodsResuspended Dust, PF 20630 Zambelli sampler, filter extraction via hot acid digestion procedure
Uncertainty Notessquare root of the quadratic sum of relative analitical uncertainties

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.006203 0.01562 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
300 - Barium 0.0005052 0.00127 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
328 - Cadmium 0.0012578 0.00693 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
329 - Calcium 0.007294 0.01837 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
347 - Chromium 0.002255 0.01242 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
380 - Copper 0.00462 0.02545 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
488 - Iron 0.21617 0.54435 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
520 - Lead 0.090392 0.4979 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
525 - Magnesium 0.002681 0.00675 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
526 - Manganese 0.015011 0.0378 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
612 - Nickel 0.0002014 0.00111 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
669 - Potassium 0.03715 0.09355 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
696 - Sodium 0.039857 0.10037 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
697 - Strontium 0.0000223 0.00006 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
767 - Vanadium 0.0000683 0.00038 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
778 - Zinc 0.358674 0.90319 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty