Relative Mass |
Uncertainty |
Analytical Method |
Uncertainty Method |
| 292 - Aluminum |
0.02757 |
0.005515 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 296 - Antimony |
0.000008 |
0.000002335 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 298 - Arsenic |
0.0000116 |
0.00000271 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 300 - Barium |
0.00055 |
0.0001112 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 328 - Cadmium |
0.001615 |
0.0003232 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 329 - Calcium |
0.1955 |
0.0391 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 337 - Chloride ion |
0.000155 |
0.00000775 |
IC, Ion chromatography |
analytical uncertainty |
| 347 - Chromium |
0.00055 |
0.0001112 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 379 - Cobalt |
0.0000268 |
0.000007824 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 380 - Copper |
0.0001538 |
0.00003092 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 488 - Iron |
0.02474 |
0.004948 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 520 - Lead |
0.0000862 |
0.00001737 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 525 - Magnesium |
0.00814 |
0.001638 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 526 - Manganese |
0.000639 |
0.0001288 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 612 - Nickel |
0.0000556 |
0.00001138 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 613 - Nitrate |
0.000506 |
0.0001043 |
IC, Ion chromatography |
analytical uncertainty |
| 626 - Organic carbon |
0.0628 |
0.01404 |
TOT thermal optical analysis NIOSH protocol |
analytical uncertainty |
| 666 - Phosphorus |
0.001615 |
0.0003232 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 669 - Potassium |
0.01025 |
0.002051 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 693 - Selenium |
0.1955 |
0.0391 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 694 - Silicon |
0.1064 |
0.02128 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 697 - Strontium |
0.0002349 |
0.000047 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 699 - Sulfate |
0.1064 |
0.02128 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 700 - Sulfur |
0.001788 |
0.0003577 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 714 - Tin |
0.0000556 |
0.00001138 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 715 - Titanium |
0.002887 |
0.0005777 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 767 - Vanadium |
0.0000699 |
0.00001485 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 778 - Zinc |
0.0003382 |
0.00006772 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 784 - Ammonium |
0.000398 |
0.00008205 |
IC, Ion chromatography |
analytical uncertainty |
| 785 - Sodium ion |
0.0000268 |
0.000007824 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 795 - Chlorine |
0.001053 |
0.0002106 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 797 - Elemental Carbon |
0.01025 |
0.002051 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 810 - Bromine |
0.0000035 |
0.0000008602 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 1847 - Tellurium |
0.00000325 |
0.000003314 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |
| 2302 - Potassium ion |
0.0021 |
0.0004329 |
IC, Ion chromatography |
analytical uncertainty |
| 2303 - Calcium ion |
0.0163 |
0.00336 |
IC, Ion chromatography |
analytical uncertainty |
| 2772 - Magnesium ion |
0.0000699 |
0.00001485 |
ED-XRF energy dispersive X-ray fluorescence |
analytical uncertainty |