Profile:
172 - Background area soil Re-suspended PM10
Code
172
Name
Background area soil Re-suspended PM10
Source categories
soil, all sources
Country
Italy
Site
Lecce
Test year
2010
Type
O
Latitude
40.351
Longitude
18.175
Reference
Cesari et al., 2012, 10.1016/j.apgeochem.2012.02.029
Notes
15 composite samples: arable land, olive grove, sand and vineyards
Sampling Methods
Raw dust (dryed and sieved at 2mm) and resuspended PM10 (TCR-Tecora). Soil was collected from the surface to a depth of 3 cm.
Uncertainty Notes
Standard Deviation
Data
Relative Mass
Uncertainty
Analytical Method
Uncertainty Method
292 - Aluminum
0.078162
0.0143323
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
296 - Antimony
0.0000132
0.0000102
AAS atomic absorption spectrometry
standard deviation
298 - Arsenic
0.0000114
0.000006
AAS atomic absorption spectrometry
standard deviation
328 - Cadmium
0.00000044
0.00000028
AAS atomic absorption spectrometry
standard deviation
329 - Calcium
0.0637077
0.0286347
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
347 - Chromium
0.000144
0.0000251
AAS atomic absorption spectrometry
standard deviation
380 - Copper
0.0001389
0.0001035
AAS atomic absorption spectrometry
standard deviation
488 - Iron
0.0398966
0.0046292
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
520 - Lead
0.0000693
0.00001
AAS atomic absorption spectrometry
standard deviation
525 - Magnesium
0.0064075
0.0011565
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
526 - Manganese
0.0011578
0.0002793
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
612 - Nickel
0.0001589
0.0000525
AAS atomic absorption spectrometry
standard deviation
669 - Potassium
0.0125332
0.0024962
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
696 - Sodium
0.0027143
0.0014732
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
715 - Titanium
0.0037627
0.0008147
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
767 - Vanadium
0.0000386
0.0000068
AAS atomic absorption spectrometry
standard deviation
778 - Zinc
0.0004811
0.0002589
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation