Profile: 172 - Background area soil Re-suspended PM10

Code172
NameBackground area soil Re-suspended PM10
Source categoriessoil, all sources
CountryItaly
SiteLecce
Test year2010
TypeO
Latitude40.351
Longitude18.175
ReferenceCesari et al., 2012, 10.1016/j.apgeochem.2012.02.029
Notes15 composite samples: arable land, olive grove, sand and vineyards
Sampling MethodsRaw dust (dryed and sieved at 2mm) and resuspended PM10 (TCR-Tecora). Soil was collected from the surface to a depth of 3 cm.
Uncertainty NotesStandard Deviation

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0,078162 0,0143323 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
296 - Antimony 0,0000132 0,0000102 AAS atomic absorption spectrometry standard deviation
298 - Arsenic 0,0000114 0,000006 AAS atomic absorption spectrometry standard deviation
328 - Cadmium 0,00000044 0,00000028 AAS atomic absorption spectrometry standard deviation
329 - Calcium 0,0637077 0,0286347 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
347 - Chromium 0,000144 0,0000251 AAS atomic absorption spectrometry standard deviation
380 - Copper 0,0001389 0,0001035 AAS atomic absorption spectrometry standard deviation
488 - Iron 0,0398966 0,0046292 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
520 - Lead 0,0000693 0,00001 AAS atomic absorption spectrometry standard deviation
525 - Magnesium 0,0064075 0,0011565 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
526 - Manganese 0,0011578 0,0002793 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
612 - Nickel 0,0001589 0,0000525 AAS atomic absorption spectrometry standard deviation
669 - Potassium 0,0125332 0,0024962 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
696 - Sodium 0,0027143 0,0014732 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
715 - Titanium 0,0037627 0,0008147 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
767 - Vanadium 0,0000386 0,0000068 AAS atomic absorption spectrometry standard deviation
778 - Zinc 0,0004811 0,0002589 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation