Profile: 172 - Background area soil Re-suspended PM10

Code172
NameBackground area soil Re-suspended PM10
Source categoriessoil, all sources
CountryItaly
SiteLecce
Test year2010
TypeO
Latitude40.351
Longitude18.175
ReferenceCesari et al., 2012, 10.1016/j.apgeochem.2012.02.029
Notes15 composite samples: arable land, olive grove, sand and vineyards
Sampling MethodsRaw dust (dryed and sieved at 2mm) and resuspended PM10 (TCR-Tecora). Soil was collected from the surface to a depth of 3 cm.
Uncertainty NotesStandard Deviation

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.078162 0.0143323 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
296 - Antimony 0.0000132 0.0000102 AAS atomic absorption spectrometry standard deviation
298 - Arsenic 0.0000114 0.000006 AAS atomic absorption spectrometry standard deviation
328 - Cadmium 0.00000044 0.00000028 AAS atomic absorption spectrometry standard deviation
329 - Calcium 0.0637077 0.0286347 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
347 - Chromium 0.000144 0.0000251 AAS atomic absorption spectrometry standard deviation
380 - Copper 0.0001389 0.0001035 AAS atomic absorption spectrometry standard deviation
488 - Iron 0.0398966 0.0046292 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
520 - Lead 0.0000693 0.00001 AAS atomic absorption spectrometry standard deviation
525 - Magnesium 0.0064075 0.0011565 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
526 - Manganese 0.0011578 0.0002793 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
612 - Nickel 0.0001589 0.0000525 AAS atomic absorption spectrometry standard deviation
669 - Potassium 0.0125332 0.0024962 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
696 - Sodium 0.0027143 0.0014732 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
715 - Titanium 0.0037627 0.0008147 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation
767 - Vanadium 0.0000386 0.0000068 AAS atomic absorption spectrometry standard deviation
778 - Zinc 0.0004811 0.0002589 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer standard deviation