FAQ
|
Privacy statement
|
Legal notice
|
Accessibility statement
|
Cookies
|
Contact JRC
|
Search
European Commission
EU Science Hub
SE
SPECIEUROPE
Source profiles for Europe database
Home
Database
Source categories
Species
PM size fraction
Countries
Sites
Test years
Additional Info
Terminology
Technical notes
How to contribute
Acknowledgments
Profile:
171 - Urban Area raw road dust
Code
171
Name
Urban Area raw road dust
Source categories
traffic, road, all sources
Country
Italy
Site
Lecce
Test year
2010
Type
O
Latitude
40.351
Longitude
18.175
Reference
Cesari et al., 2012, 10.1016/j.apgeochem.2012.02.029
Notes
Sampling Methods
Raw dust (dryed and sieved at 2mm) and resuspended PM10 (TCR-Tecora). Sampling via road manually sweeping the road (on the sides of both carriageways)
Uncertainty Notes
Standard Deviation
Data
Relative Mass
Uncertainty
Analytical Method
Uncertainty Method
292 - Aluminum
0.0061322
0.0002389
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
296 - Antimony
0.0000017
0.0000019
AAS atomic absorption spectrometry
standard deviation
298 - Arsenic
0.0000058
0.0000007
AAS atomic absorption spectrometry
standard deviation
328 - Cadmium
0.00000039
0.00000004
AAS atomic absorption spectrometry
standard deviation
329 - Calcium
0.261784
0.0484617
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
347 - Chromium
0.0000162
0.0000025
AAS atomic absorption spectrometry
standard deviation
380 - Copper
0.0000699
0.0000243
AAS atomic absorption spectrometry
standard deviation
488 - Iron
0.0055811
0.0001908
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
520 - Lead
0.0000358
0.0000411
AAS atomic absorption spectrometry
standard deviation
525 - Magnesium
0.0658024
0.0056835
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
526 - Manganese
0.0000864
0.0000001
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
612 - Nickel
0.0000069
0.0000003
AAS atomic absorption spectrometry
standard deviation
669 - Potassium
0.0025397
0.0002249
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
696 - Sodium
0.0016247
0.0002702
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
715 - Titanium
0.0006661
0.000019
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation
767 - Vanadium
0.0000219
0.0000035
AAS atomic absorption spectrometry
standard deviation
778 - Zinc
0.0002048
0.0001063
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
standard deviation