Profile:
143 - Bell metal casting
Code
143
Name
Bell metal casting
Source categories
industry, foundry, metallurgy, all sources
Country
Turkey
Site
Izmir
Test year
2005
Type
O
Latitude
38.419
Longitude
27.129
Reference
Yatkin et al, 2008, 10.1016/j.chemosphere.2007.10.070
Notes
Sampling Methods
Resuspended Dust, PF 20630 Zambelli sampler, filter extraction via hot acid digestion procedure
Uncertainty Notes
square root of the quadratic sum of relative analitical uncertainties
Data
Relative Mass
Uncertainty
Analytical Method
Uncertainty Method
292 - Aluminum
0.0010393
0.0013
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
300 - Barium
0.0000168
0.00002
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
328 - Cadmium
0.0002781
0.00035
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
329 - Calcium
0.0004113
0.00051
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
347 - Chromium
0.0000096
0.00001
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
380 - Copper
0.012694
0.01586
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
488 - Iron
0.0009081
0.00113
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
520 - Lead
0.0159496
0.01992
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
525 - Magnesium
0.0001434
0.00018
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
526 - Manganese
0.0000463
0.00006
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
612 - Nickel
0.0000023
0
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
669 - Potassium
0.0004217
0.00053
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
696 - Sodium
not detected
not detected
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
697 - Strontium
0.0000041
0.00001
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
767 - Vanadium
0.0000035
0
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty
778 - Zinc
0.2877639
0.35944
ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer
analytical uncertainty