European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 110 - Aluminium rim production

Code110
NameAluminium rim production
Source categoriesindustry, foundry, metallurgy, all sources
CountryTurkey
SiteIzmir
Test year2005
TypeO
Latitude38.419
Longitude27.129
ReferenceYatkin et al, 2008, 10.1016/j.chemosphere.2007.10.070
Notesfrom stack of paint booth
Sampling MethodsIn-stack cyclone, PF 20357/8 Zambelli sampler, filter extraction via hot acid digestion procedure
Uncertainty Notessquare root of the quadratic sum of relative analitical uncertainties

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0,0082502 0,02475 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
300 - Barium 0,001476 0,00443 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
328 - Cadmium 0,0000021 0,00001 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
329 - Calcium 0,0041522 0,01246 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
347 - Chromium 0,0003609 0,00108 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
380 - Copper 0,0001521 0,00046 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
488 - Iron 0,0049854 0,01496 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
520 - Lead 0,0001016 0,00031 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
525 - Magnesium 0,0026213 0,00786 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
526 - Manganese 0,0000712 0,00021 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
612 - Nickel 0,0002454 0,00074 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
669 - Potassium 0,0004318 0,0013 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
696 - Sodium 0,0006949 0,00208 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
697 - Strontium 0,000051 0,00015 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
767 - Vanadium 0,0000285 0,00009 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
778 - Zinc 0,0005346 0,0016 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty