European Commission EU Science Hub SE

SPECIEUROPE

Source profiles for Europe database

Profile: 105 - Steel plants with electric arc furnaces

Code105
NameSteel plants with electric arc furnaces
Source categoriesindustry, iron and steel, all sources
CountryTurkey
SiteIzmir
Test year2005
TypeO
Latitude38.419
Longitude27.129
ReferenceYatkin et al, 2008, 10.1016/j.chemosphere.2007.10.070
Notesfrom bag filter of electric arc furnace of steel production from scrap
Sampling MethodsResuspended Dust, PF 20630 Zambelli sampler, filter extraction via hot acid digestion procedure
Uncertainty Notessquare root of the quadratic sum of relative analitical uncertainties

Data

  Relative Mass Uncertainty Analytical Method Uncertainty Method
292 - Aluminum 0.0090383 0.06426 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
300 - Barium 0.0005283 0.00042 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
328 - Cadmium 0.0012076 0.00005 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
329 - Calcium 0.0183758 0.12673 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
347 - Chromium 0.0071589 0.00036 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
380 - Copper 0.0056094 0.00025 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
488 - Iron 0.247086 0.06925 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
520 - Lead 0.0844367 0.00365 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
525 - Magnesium 0.0035124 0.01451 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
526 - Manganese 0.0162831 0.00216 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
612 - Nickel 0.0024006 0.00065 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
669 - Potassium 0.0361828 0.0157 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
696 - Sodium 0.03972 0.00416 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
697 - Strontium 0.0000319 0.00021 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
767 - Vanadium 0.0000812 0.00047 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty
778 - Zinc 0.328902 0.00051 ICP-OES (AES), Inductively Coupled Plasma Optical (Atomic) Emission Spectrometer analytical uncertainty