Relative Mass |
Uncertainty |
Analytical Method |
Uncertainty Method |
296 - Antimony |
0.000011989365564 |
0.000012007209483 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
298 - Arsenic |
0 |
0.000002547050071 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
300 - Barium |
0.000020812957783 |
0.0000488609687 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
328 - Cadmium |
0 |
0.000001628386836 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
337 - Chloride ion |
0.316854940314762 |
0.041910267769049 |
IC, Ion chromatography |
standard deviation |
347 - Chromium |
0 |
0.000024707250244 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
379 - Cobalt |
0 |
0.000001015807075 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
380 - Copper |
0 |
0.000049217446665 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
488 - Iron |
0.010711311366888 |
0.003401154996238 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
520 - Lead |
0.000099893228555 |
0.000079700182052 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
526 - Manganese |
0.000259817634372 |
0.000094769560835 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
586 - Molybdenum |
0 |
0.000001977088758 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
612 - Nickel |
0 |
0.000002331419211 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
613 - Nitrate |
0 |
0.0480885343236 |
IC, Ion chromatography |
standard deviation |
626 - Organic carbon |
0.033249695701382 |
0.037597118473219 |
TOT thermal optical analysis EUSAAR2 protocol |
standard deviation |
693 - Selenium |
0 |
0.000005761942398 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
697 - Strontium |
0.000334824574516 |
0.00005049798422 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
699 - Sulfate |
0.105673834589677 |
0.038353256879915 |
IC, Ion chromatography |
standard deviation |
714 - Tin |
0.000056658267313 |
0.000033434650992 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
715 - Titanium |
0.000506769309616 |
0.000094638030857 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
767 - Vanadium |
0 |
0.000038108185013 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
778 - Zinc |
0.000013798073843 |
0.000158583111611 |
ICP-MS, inductively coupled plasma mass spectrometry |
standard deviation |
784 - Ammonium |
0 |
0.006402361030479 |
IC, Ion chromatography |
standard deviation |
785 - Sodium ion |
0.236338593606526 |
0.030364949582636 |
IC, Ion chromatography |
standard deviation |
797 - Elemental Carbon |
0.035700100365158 |
0.013052198739274 |
TOT thermal optical analysis EUSAAR2 protocol |
standard deviation |
955 - Levoglucosan |
0.000101191569327 |
0.000406760525085 |
HPAEC-PAD high performance anion exchange chromatography-pulsed amperometric detection |
standard deviation |
2302 - Potassium ion |
0.008087723419249 |
0.001292573323978 |
IC, Ion chromatography |
standard deviation |
2303 - Calcium ion |
0.020374127143437 |
0.006764396882609 |
IC, Ion chromatography |
standard deviation |
2750 - Mannosan |
0 |
0.000032119693337 |
HPAEC-PAD high performance anion exchange chromatography-pulsed amperometric detection |
standard deviation |
2772 - Magnesium ion |
0.0159900916099 |
0.002456090092836 |
IC, Ion chromatography |
standard deviation |
2806 - Sorbitol |
0 |
0 |
HPAEC-PAD high performance anion exchange chromatography-pulsed amperometric detection |
standard deviation |
3017 - Methanesulfonic acid |
0.00145529479596 |
0.000843666886317 |
IC, Ion chromatography |
standard deviation |